                                                 Surface Texture Variations (Wet Cast)
                                                 All surfaces intended to be exposed to view shall have no air voids greater than 0.8 mm
                                                 and the density of such voids shall be less than three occurrences per 25 mm square.
                                                 Repairs
                                                 Repairs to cast stone shall be acceptable if the repairs conform to the other requirements
                                                 above.
                                                 Repairs can range from minor filling of blemishes through to a reconstruction of the piece
                                                 with a full surface coating. Significant differences in colour may exist between the properly
                                                 repaired areas and the original castings when the time elapsed between the date of
                                                 manufacture and the date of the repair is great. The repaired areas should be left alone
                                                 and should blend in over time due to the action of curing, natural weathering and sunlight,
                                                 as mentioned under Colour Variations.
                                                 Dimensional Requirements
                                                 Shall be in accordance with the British/UKCSA Standard.