Page 44 - Haddonstone
P. 44

44

    Appendix 3 – The UKCSA Specification

    •	 Cast stone units:

    	 –	 Manufacturer: 	        Member of the United Kingdom Cast Stone Association

    			                         (UKCSA).

    			                         (See www.ukcsa.co.uk/membership.php for a list of current members)

    	 –	 Manufacturing process: 	 In accordance with the UKCSA Operating Standard

    	 –	 Method of manufacture:	 Wet cast *

    			                         Semi-dry cast *

    			                         Fibre reinforced cast stone *

    			                         (* include the method of manufacture required as appropriate)

    	 –	 Product references: 	  To approved details

    	 –	 Absorption:	           To BS 1217: 2008, CAT method

    	 –	 Compressive strength: 	 To BS 1217: 2008

    		 Cube strength testing to be carried out on a minimum of a weekly basis

    		 Cubes cured in accordance with BS EN 12390-2

    		 Cubes crushed in accordance with BS EN 12390-3

    	 –	 Average cube strength:	 Minimum 35 MPa (35 N/mm2)

    		 Single cube strength:	 Minimum 28 MPa (28 N/mm2)

    	 –	 Finish:	               To approved sample

    	 –	 Colour:	               To approved sample

    •	 Mortar: 	                To BS 5628-3: 2005

    •	 Joints:	                 Flush pointed

    	 –	 Width:	                6 mm **

    			                         10 mm **

    			                         (** include the joint width required as appropriate)

    •	 Other Requirements:	     None